PEB1590EJ1ES General Electric Microwave - Overview
Sections of the PEB1590EJ1ES
[Viewing 4 of 4]Keep searches simple, eg. "belt" or "pump".

Microwave Fuse
PartSelect #: PS3486694
Manufacturer #: WB27X11138
This fuse is for microwaves. Fuse protects the microwave from damage by shutting off the microwave if there's a power surge.
$54.40
In Stock

Glass Turntable Tray
PartSelect #: PS3486810
Manufacturer #: WB39X10032
This turntable tray is for microwaves.
Turntable tray rotates in the center of the microwave to help ensure the food cooks evenly.
Follow the instructions in the owner's manual when installing this part.
$135.31
In Stock

Microwave Door Interlock Switch Bracket
PartSelect #: PS3486543
Manufacturer #: WB14X10049
The door interlock switch bracket houses and supports the door switches.
$47.95
In Stock

LEVER SWITCH
PartSelect #: PS12170282
Manufacturer #: WB10X27080
Presenting the GE Lever Switch, an essential component for your microwave. This door interlock switch lever serves a critical duty - it activates the interlock switch whenever the microwave door is cl...
$36.95
In Stock

Turntable Motor
PartSelect #: PS12722592
Manufacturer #: WB26X32190
This turntable motor is for microwaves.
The turntable motor rotates the glass tray inside the microwave oven.
Because high-voltage capacitors in a microwave can retain a lethal electrical charge...
$66.28
In Stock

Turntable Motor Coupler
PartSelect #: PS8753744
Manufacturer #: WB06X10925
The turntable motor coupler connects the turntable motor to the turntable tray to rotate the tray.
$27.95
In Stock

ROTATING RING Assembly
PartSelect #: PS11736250
Manufacturer #: WB02X27104
Introduce an important component for your kitchen needs with the GE Rotating Ring Assembly. This high-quality product is an essential for the proper functioning of your microwave, aiding in evenly dis...
$47.95
In Stock

RANGE FOOT
PartSelect #: PS12170163
Manufacturer #: WB01X27076
Sold individually.
$20.95
Special Order
Questions And Answers for PEB1590EJ1ES
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
Sort by:
- < Prev
- 1
- Next >
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Don
March 28, 2023
Unit will run approximately 30 seconds, then shutdown, Display PL code.
PL = Power Loss. If clock is reset, the unit will duplicate fault (run about 30 seconds, shutdown and display PL. Would a new magnetron fix this problem or could it be something else?
For model number PEB1590EJ1ES
Hi Don, thank you for reaching out. According to our research, you may need to check the following parts to fix this issue: high voltage capacitor, part number PS12170431, high voltage transformer, part number PS11762497, and magnetron, part number PS11773832. If the issue is not resolved, you may need to check the control panel assembly, part number PS11736507. We hope this solves your issue.
Was this helpful?
Thank you for voting!
Related Parts:
- < Prev
- 1
- Next >
Common Symptoms of the PEB1590EJ1ES
[Viewing 3 of 3]Won’t turn on
Fixed by
these parts
these parts

Show All
Door stuck closed
Fixed by
these parts
these parts

Show All
Noisy
Fixed by
these parts
these parts

Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
WHEN. YOU OPEN THE DOOR THE TURN TABLE WAS CONSTANTLY RUNNING
REPLACE SWITCH -STAND ON (NOT THE SWITCH-MONITOR) THERE ARE TWO OF THESE SWITCHES THE TOP ONE WAS DEFECTIVE.
THE ON OFF SWITCH BUTTON ON THE SWITCH WAS BROKEN
THE ON OFF SWITCH BUTTON ON THE SWITCH WAS BROKEN
Parts Used:
-
Moin from SCOTTSDALE, AZ
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
5 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave door was hard to open
1. Take out the case by unscrew 8 screws on the back and side of the case
2. Take out the control panel by unscrew 1 screw on the top and slide up
3. Take out the latch by unscrew 2 screws, and slide out 3 electric switches that clipped on the latch
4. Clip the switches onto the new latch
5. Slide in lever switch into ... Read more latch
6. Put back the latch
7. Put back the control panel
8. Put back the case
2. Take out the control panel by unscrew 1 screw on the top and slide up
3. Take out the latch by unscrew 2 screws, and slide out 3 electric switches that clipped on the latch
4. Clip the switches onto the new latch
5. Slide in lever switch into ... Read more latch
6. Put back the latch
7. Put back the control panel
8. Put back the case
Read less
Parts Used:
-
Henry from NORWALK, CT
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
4 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door locks. Not opening.
Slide a Butter knife at left side by open push knob door will open. Then open all screws from top cover push cover top side front way then door locks Bracket have 3 microswitch pulls out switches mark them top medium and bottom. Remove 3 screws holding brackets will come out. On bottom see a Cam has 1/4” holes can holding Saft broken then
... Read more
install new door lock bracket install microswitch put 3screw and slide Cam on saft . I put a small screw on saft to hold cam on place. There was no screw . That’s why cam saft was broke. Put top cover tight all the screws and door lock fixed.
Read less
Parts Used:
-
Jay from WESLEY CHAPEL, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers
4 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!