Remote Control Assembly – Part Number: AKB73795706
Remote Control Assembly
★★★★★
★★★★★
(6)
PartSelect #: PS11760970
Manufacturer #: AKB73795706
This remote control is a device for adjusting your air conditioner settings. It requires two AAA batteries for operation. A malfunctioning remote control may have unresponsive buttons or signs of phys...
$49.42
  In Stock
Order now and your part arrives in 2-3 business days!
Fan,Axial – Part Number: 5900A10011A
Fan,Axial
★★★★★
★★★★★
(4)
PartSelect #: PS3528571
Manufacturer #: 5900A10011A
  No Longer Available
Clamp,Spring – Part Number: 3H02932C
Clamp,Spring
PartSelect #: PS3522763
Manufacturer #: 3H02932C
The fan blade clamp, also known as a clamp spring, are for air conditioners. The clamp supports the fan blade on the motor shaft. When the motor is running, it signals the shaft to turn and rotate, bu...
  No Longer Available
PCB ASSEMBLY,DISPLAY – Part Number: EBR83548602
PCB ASSEMBLY,DISPLAY
★★★★★
★★★★★
(1)
PartSelect #: PS12080893
Manufacturer #: EBR83548602
Designed to optimize your room air conditioning experience, the LG Display and Power control board is a crucial component that enhances your unit's functionality. It effortlessly showcases the selecti...
$88.49
  In Stock
Order now and your part arrives in 2-3 business days!
POWER CORD ASSEMBLY – Part Number: EAD63469504
POWER CORD ASSEMBLY
★★★★★
★★★★★
(2)
PartSelect #: PS11710151
Manufacturer #: EAD63469504
$96.18
  On Order
PCB ASSEMBLY,MAIN – Part Number: EBR83604004
PCB ASSEMBLY,MAIN
★★★★★
★★★★★
(1)
PartSelect #: PS12080905
Manufacturer #: EBR83604004
$88.49
  In Stock
Order now and your part arrives in 2-3 business days!
Fan Assembly,Turbo – Part Number: 5901A20009A
Fan Assembly,Turbo
PartSelect #: PS3528634
Manufacturer #: 5901A20009A
  No Longer Available
Capacitor,Film,Box – Part Number: EAE60682902
Capacitor,Film,Box
★★★★★
★★★★★
(1)
PartSelect #: PS3533468
Manufacturer #: EAE60682902
  No Longer Available
HARNESS,MULTI – Part Number: EAD63989002
HARNESS,MULTI
PartSelect #: PS12080083
Manufacturer #: EAD63989002
$34.46
  In Stock
Order now and your part arrives in 2-3 business days!
INSTALL PART ASSEMBLY,SINGLE – Part Number: AET73691406
INSTALL PART ASSEMBLY,SINGLE
PartSelect #: PS12714363
Manufacturer #: AET73691406
$88.49
  On Order
HARNESS,MULTI – Part Number: EAD63989001
HARNESS,MULTI
★★★★★
★★★★★
(1)
PartSelect #: PS12080082
Manufacturer #: EAD63989001
$28.67
  In Stock
Order now and your part arrives in 2-3 business days!
Louver,Vertical – Part Number: 4758A30050A
Louver,Vertical
PartSelect #: PS3523412
Manufacturer #: 4758A30050A
  No Longer Available

Questions And Answers for LW2516ER

Be the first to ask our experts a question about this model!

Common Symptoms of the LW2516ER

[Viewing 1 of 1]
Noisy
Fixed by
these parts
Fixing
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
accumulated condensation caused condenser fan failure
Pull the unit out of cabinet. Remove the brace between the blower housing and the condenser frame. Remove the screws securing the the condenser coil to the base and carefully lift and angle it just enough for the broken fan to clear ( be very careful with the refrigerant lines ). Slide the new fan back on the shaft and secure with the spring clamp. I used a pair of vice grips to compress the clamp, but be very careful because the clamp can exit the pliers, if the jaws are not perpendicular to the clamp. If you live in a area with high humidity remove the rubber plug at the back of the unit or the condensation will break your new fan. This fan needs some changes in design because the condensation puts too much stress on the plastic that contacts the motor shaft - some metal between shaft and the blades would help.
Parts Used:
Fan,Axial Clamp,Spring
  • Sam from MCQUEENEY, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
17 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Fan
Part of the fan blade broke on my AC unit and was causing a vibration. This made the AC unusable. The ordered Fan was a perfect OE replacement. I simply removed the outside over and then the fan shroud inside the unit. I carefully repositioned the condenser unit being careful not to damage the fins. Using a pair of pliers, I removed the retainer clip and removed the old fan. The new fan slid right over the shaft. I replaced the retaining clip and then repositioned the shroud. Then I placed the condenser and fins back into place and then placed the cover back over the unit. Worked perfect. No issues. Take your time. Excellent replacement fan!
Parts Used:
Fan,Axial
  • April from EASLEY, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!