FCFI308CASA Electrolux Range - Overview
Sections of the FCFI308CASA
[Viewing 4 of 4]Keep searches simple, eg. "belt" or "pump".

Leveling Leg
PartSelect #: PS977569
Manufacturer #: 316272900
This part is sold individually. The leveling leg is black in color and measures approximately 2 inches in length. It is made of plastic. The leveling leg is found underneath your range and may crack o...
$21.95
In Stock

Rack
PartSelect #: PS16731592
Manufacturer #: 5304531722
Measurements: approximately 22 7/8" x 16 1/4"
$53.30
In Stock

SWITCH
PartSelect #: PS8692370
Manufacturer #: 808136601
This Frigidaire Oven Door Light Switch is a genuine OEM part, compatible with certain models of Frigidaire, Electrolux, White Westinghouse, and Tappan stoves, ovens, and ranges. Designed for functiona...
$43.95
In Stock
Questions And Answers for FCFI308CASA
Be the first to ask our experts a question about this model!
✖
Ask a Question
Ask our experts a question on this model and we'll respond as soon as we can.
Sorry, we couldn't find a match for "".
Here's a guide for finding your model number.
Something went wrong. Please try again later.
Your Question Has Been Submitted!
Our experts will send you an email as soon as your question has been answered.
Common Symptoms of the FCFI308CASA
[Viewing 1 of 1]Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
left terminal broke off from the base of the block causing circuit breaker to trip and not able to be re-set
Ensured breaker was off. My range is hot wired. Removed all cables from old terminal block with nutdriver. Used phillips head screw driver to remove old terminal block from back of range. replaced old terminal block with new one. Re-attached accessory cables to small terminals first, then the main cables to the terminal block using where
... Read more
necessary long nose pliers. It is important to make note of which cables are attached to each terminal of the block, so make a sketch PRIOR to removal. Also be careful how the cables are attached to the block. You are using 10 gauge cable with thick insulation. It is important that when pushing the range back into position the cable does not put too much pressure on the block as it will break it. That's exactly what happened to this last one. It probably cracked under the strain of the pressure of the cable and finally current running through it weakened it to the point where it broke off from the block causing it to short and trip the breaker.
Read less
Parts Used:
-
Fred from North Babylon, NY
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers, Screw drivers
0 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!