Refrigerator Timers
Popular Refrigerator Timers
38% OFF
Your Price
$28.03
$45.49
In Stock
Refrigerator DEFROST TIMER
PartSelect Number PS12585793
Manufacturer Part Number 5304518034
This is a 120 volt defrost timer manufactured for refrigerators. The defrost timer manages the automatic defrost systemin the unit. It acts like a clock by switching between activating the cooling cycle and the defrost heater to maintain the set thermostat temperature, preventing the unit from being too warm or cold. The defrost timer may need to be replaced if the fridge will not maintain its temperature or has frost buildup. Depending on the model, it could be located on the rear panel or ceiling of the fresh food compartment. Be sure to disconnect power to the refrigerator before replacing this part.
Fixes these symptoms
- Doesn’t stop running
- Fridge too warm
- Frost buildup
- See more...
Installation Instructions
James from Navarre, FL
After getting wiring diagram off internet it was diagnosed as freezer stuck in defrost mode, temp alarm on, but fan running.
Turned gray knob on defrost timer (located bottom left back of freezer) past defrost position to verify compressor would run...it would not, but fan would run. Tested run capacitor...found borderline defective (weak, wrong value ohm meter kick). Just to be sure, removed interior shelves and interior rear and gasket to check heater at 20 ohms as OK and removed thermostat and verified contact closure after exposure in another freezer....re-installed, hooked heater back up and re-installed interior rear panel. Replaced defrost timer by unplugging 4-pin connector, then removed 2 screws that hold it to the bracket. Installed new one in reverse order. Then removed wire bail holding run capacitor to compressor plug assembly, removed run capacitor, plugged in new one. Turned on freezer......now making ice and holding cold temperature and cycling properly between freeze and defrost modes. Two problems made this repair a bit more difficult. This is the second time that defrost timer has failed...only got 3 years from last one.
Read more...
Your Price
$38.60
In Stock
Refrigerator Defrost Timer - 60Hz 120V
Pulled plug.
Had to remove bottom drawers then used nut driver to remove screws closest to back wall in drawer runners. Once the back screws were removed the runners could be swung up or down out of way so back cover could be removed.
Once back cover was removed thermostat was located attached to top pipe going into coil using a spring clamp.
Cut the wires just outside the crimp connectors going into thermostat. Released the spring clamp buy squeezing botton together.
Removed old badly corroded thermostat.
I wish I had attached the crimp connectors to the new thermostat wires before mounting it. Reaching way in the back, while turning shoulders verticly and trying to get the wire connectors set from both sides was awkward and uncomfortable...The biggest PIA of the whole task.
Once connected I let the fridge (thermostat) cool for 10 min. Turned the dial defrost timer to get it into defrost mode. Stupidly touched the heating element to see if it was getting warm...it was very hot.
Coils steamed...every looked like it was working. Unplugged, put back cover back on and retattached drawer mounts.
Plugged back in and everying is working great! Read more...
PartSelect Number PS423801
Manufacturer Part Number 215846602
This Defrost Timer works like a clock by switching on the defrost heater circuit after a predetermined amount of compressor run time. This allows the defrost circuit to clear the evaporator of ice or frost to maintain proper airflow. The defrost timer is located in the control housing which is in the refrigerator section of your appliance. If this part is not working, it can lead to temperature increases in your refrigerator. If the compressor circuit fails, no cooling will take place; if the defrost circuit isn't activated, ice will quickly build up on the evaporator coils and reduce airflow and efficiency. If the timer doesn't advance or if the contacts have no continuity, the timer will need to be replaced. This timer measures approximately 3 inches long and 2.5 inches wide, and is constructed of plastic and metal. It comes in black/white/silver and is sold individually. This replacement part features 1 defrost timer.
Fixes these symptoms
- Freezer not defrosting
- Freezer section too warm
- Freezer too cold
- See more...
Installation Instructions
Stephen from Warrington, PA
Fridge got warm and freezer coils were frosted
Fridge is a side by side. The freezer is pretty narrow for a guy with wide shoulders. Pulled plug.
Had to remove bottom drawers then used nut driver to remove screws closest to back wall in drawer runners. Once the back screws were removed the runners could be swung up or down out of way so back cover could be removed.
Once back cover was removed thermostat was located attached to top pipe going into coil using a spring clamp.
Cut the wires just outside the crimp connectors going into thermostat. Released the spring clamp buy squeezing botton together.
Removed old badly corroded thermostat.
I wish I had attached the crimp connectors to the new thermostat wires before mounting it. Reaching way in the back, while turning shoulders verticly and trying to get the wire connectors set from both sides was awkward and uncomfortable...The biggest PIA of the whole task.
Once connected I let the fridge (thermostat) cool for 10 min. Turned the dial defrost timer to get it into defrost mode. Stupidly touched the heating element to see if it was getting warm...it was very hot.
Coils steamed...every looked like it was working. Unplugged, put back cover back on and retattached drawer mounts.
Plugged back in and everying is working great! Read more...
Your Price
$161.75
In Stock
Refrigerator Electronic Control Board
PartSelect Number PS11755733
Manufacturer Part Number WPW10503278
The electronic control board is used in refrigerators to monitor and manage the temperature settings, such as cooling or defrosting times. If your fridge or freezer is too warm, too cold, is not defrosting, will not start, and/or runs too long then replacing the control board could solve your appliance problem. The tools needed for this installation project is a small flat blade screwdriver. *Please note: the board will need to be programmed after installation. Remember to unplug refrigerator from power source as a safety precaution. Refer to the manual provided by the manufacturer for further installation instructions and accurate guidance.
Fixes these symptoms
- Freezer not defrosting
- Freezer section too warm
- Freezer too cold
- See more...
Installation Instructions
Russell from Hardinsburg, KY
Freezer is cold, Refridgerator is not as cold as it should be
Having seen this problem before in other equipment so I had an idea where to look. Problem: the automatic defrost function was not operating. Looking through openings in the back panel of the freezer compartment, you could see the evaporator coils and fins were a solid chuck of ice. There are three logical components to check. Heater element, thermostat (located just above the evaporator) and a relay on the control board (located in the fridge control panel). Checked the heater with an ohm meter -- OK. The thermostat closes the circuit at around 20 degrees and opens at around 32 degrees. Pulled out the thermostat, wiring, fan unit. Everything unplugs, unscrews, and unclips, don't cut wires. Put the whole assembly in a friends freezer for an hour or so to see if the thermostat closes -- OK. Problem had to be with the control board. Replaced control board, reprogrammed it per included instruction. Everything is working again.
Read more...
Your Price
$35.85
In Stock
Refrigerator Defrost Timer
PartSelect Number PS11723171
Manufacturer Part Number W10822278
The Defrost Timer (Defrost control) acts like a clock by switching on the defrost heater circuit after a predetermined amount of compressor run time. This allows the defrost circuit to clear the evaporator of ice or frost to maintain proper airflow. If this part is not working, it can lead to temperature increases in your refrigerator. If the compressor circuit fails, no cooling will take place; if the defrost circuit isn't activated, ice will quickly build up on the evaporator coils and reduce airflow and efficiency. If the timer doesn't advance or if the contacts have no continuity, the timer will need to be replaced. This part is located inside of the control housing on most models, and is approximately 3 inches long and 2.5 inches wide. This part is constructed of plastic and metal, and comes in white. It features 1 defrost timer, along with all necessary mounting hardware and installation instructions
Fixes these symptoms
- Freezer not defrosting
- Freezer section too warm
- Freezer too cold
- See more...
Installation Instructions
Lawrence from Grahamsville, NY
The frost free feature of the freezer was freezing over with ice and cooling coils were being insulated with thickening frost which caused the cooling air to rise in temperature from -5 degrees to 20 degrees.
I troubleshot the problem by reading the electrical schematic and concluding the heating elements (defrost cables) were either defective or the bi-metal temp sensor was open. When closed the temp sensor completes the circuit for the current to flow through the heaters to defrost the cooling coils every 8 hours and then when the bimetal opens at 55 degrees the circuit is open and the coils are cooled because the refridgeration motor is in run mode. A timer between the motor and heater elements also was defective. The timer controls the cooling period and the defrost period. I ohmed out each part according to the spec sheet of normal resistance of parts and thus the bimetal and timer were defective. I gather a surge of some duration and amplitude affected these parts because a storm 24 hours prior to refridgerator problem had passsed through the area and the AC electrical power had oscillated several times during that event. I used hand tools to do the repair. If you are not mechanically inclined a step by step proceedure would be moot. It is a matter of disassembly and assembly paying close attention to fragile parts.
Read more...
Refrigerator Defrost Timer - 120V 60Hz
PartSelect Number PS423802
Manufacturer Part Number 215846604
This defrost timer is designed for use in your refrigerator. The defrost timer acts as a clock, that switches the refrigerator from the freezing cycle to the defrost cycle and back. If your refrigerator is running non-stop, or is not running at all, you may need to check and replace the defrost timer. This is a 6 hour and 21 minute defrost timer. This part is made of white plastic, with 4 metal prongs protruding from one end. To complete this repair, you will need to access the old defrost timer which is located inside the console on the roof of your refrigerator. To complete this repair, you will need a 1/4-inch nut driver, a flat blade screwdriver, and a Phillips screwdriver. Be sure to disconnect power from your refrigerator before you begin this repair.
Fixes these symptoms
- Freezer not defrosting
- Freezer section too warm
- Fridge and Freezer are too warm
- See more...
Installation Instructions
Dennis from BEAUMONT, TX
Freezer Freezing up and blocking the vent for refrigerator, not cooling the fridge.
Went pretty straight forward, except the heat shrink tubing was about 2 sizes too big. Would not shrink small enough to seal the connections. Even with a heat gun it would not shrink small enough. OH, another think is when I plugged the fridge back in the defrost timer was in defrost mode. Took me a few minutes to figure that out and use a screwdriver to turn the timer back to the on position. Other than that, install was pretty simple.
Read more...
Your Price
$93.21
In Stock
Refrigerator Defrost Timer - 120V 60Hz
PartSelect Number PS310869
Manufacturer Part Number WR9X502
This defrost timer will cycle for 25 minutes after every six hours of run time. The timer itself is made of plastic, and its terminals are bent, the leads are internal, and the label is orange. If you notice that your fridge is too warm, the fridge is running for a long time or is leaking, it could be due to the defrost timer becoming inactive. The defrost timer is found underneath the light cover (may need to remove lightbulb) and will need to be removed along with the air inlet assembly and housing.
Fixes these symptoms
- Freezer not defrosting
- Freezer section too warm
- Freezer too cold
- See more...
Installation Instructions
Wanda from Cabins, WV
refrigerator was not cooling but the freezer worked fine.
My husband put on the defrost timer. At first I thought the part was not going to fix the problem. After about 5 hours my refrigerator was still warm. I went to work and when I got home that evening my refrigerator was cooling and down to 28 degrees. So if you replace this part wait at least 12-24 hours. Give it time to stablize. My husband says it has to go through its cycle. It works on a 24 hour timer. My refrigerator is working fine and this has saved me alot of money. My husband says, once you put on the timer you may have to use a flat screwdriver and turn the small dial clockwise one click to start it. He removed the kick grill and replaced the part. Dont forget to shut breaker off to replace this part. Turn power back on and start the timer. We are so happy that we now have a working refrigerator.
Read more...
Your Price
$50.67
In Stock
Refrigerator Defrost Timer
PartSelect Number PS310858
Manufacturer Part Number WR9X489
This device acts like a clock. It continually advances and alternates between activating the cooling cycle and the defrost heater.
Fixes these symptoms
- Freezer not defrosting
- Freezer section too warm
- Freezer too cold
- See more...
Installation Instructions
Richard from West Alton, MO
Freezer was still simi-cold but refrigerator was not.
Called a friend that lead me down the right path so i did a search for the part's and found this site. The trouble shooting that outher's had done was the same as mine, I descovered that the coil's in the freezer had frozen up complety. They are located behind a plasic cover in the freezer area, it had frozen up due to the Defrost heater element being defective, when i took it out it was black and burnt looking,It is located at the bottom edge of the coils,2 bolt's and a plug in on each side. That is probally the only part i needed but i went ahead and replaced the sensor and timer also.The sensor wires in the freezer( located on the very top of the coils) had to be cut and the new ones spliced in, only 2 wires and easy access. I also put shrink wrap on the splices to protect them from mosisture. The timer was located in the fridge area by the temp. control knobs. 2 small bolts and a plug in was all on it. It's been 5 day's and so far so good. The worst part was defrosting the frozen coils. This was done with the wife's hair dryer and a couple towel's to soak up the water. Don't just let the water go down the drain hole because the tray that catches it will not hold all the water from the frozen coil's. Just a reminder, don't forget to unplug the unit when working on it. Hope this help's and was very easy install, Cost about $125 in part's and a couple hours of labor(did a good cleaning while it was eampty for the repair) Good luck.
Read more...
Your Price
$31.79
In Stock
Refrigerator Defrost Timer Kit - 120V 60Hz
PartSelect Number PS2167006
Manufacturer Part Number R0131577
The timer will shut off the cooling system of the refrigerator and the defrost heater will turn on.
Fixes these symptoms
- Freezer not defrosting
- Freezer section too warm
- Freezer too cold
- See more...
Installation Instructions
Peter from Eden, UT
Fridge and freezer didn't cool enough
I diagnosed the problem via the internet. Diagrams helped a lot. Coils were frozen over. Thawed them out overnight. Manually advanced timer and the defrost heater was operable. The defrost timer wasn't "turning" on it's own. I turned the fridge back on while I awaited the part. It worked fine for the time I had to wait. (over two weeks since I had delayed ordering the part) New timer arrived as promised. Undid 4 hex head (1/4") screws. Unplugged 4 prong connection. Plugged in new timer and replaced the 4 screws. Frigde works great.
Read more...
Refrigerator Electronic Control
PartSelect Number PS11752535
Manufacturer Part Number WPW10310240
This electronic board manages and monitors the cooling and defrost times of your refrigerator and other functions. If your refrigerator is not cooling properly because the dispenser is flapping between open or closed positions, or there are problems with the display lights flashing, replacing your control board can be the solution. Remember to unplug your refrigerator from the power source before beginning this installation project. Refer to the manual provided by the manufacturer for installation instructions and accurate guidance.
Fixes these symptoms
- Will Not Start
- See more...
Installation Instructions
Roy from BARTLETT, TN
Refrigerator quit except for the light inside.
Removed the metal cover over the HV electronic board on the back of the unit. Using a flat head screwdriver I unsnapped the plastic cover and removed it. I unplugged the 5 or 6 cables from the electronic board. Bent back the plastic tabs holding the board. You might think they are going to break but they bend. I lifted the board out and replaced it with the new one. Then plugged the cables in being careful to align them first. I then applied power and the refrigerator came to life. I followed the programming instructions that came with the refrigerator. You can get those online also. The unit began to run and in a few minutes the compressor came on. The unit began cooling and life was good again!